Hydrostatic pressure and fluid replacement calculator

Work out the pressure exerted by a column of liquid, and how that pressure changes when the fluid is swapped for a lighter or heavier one. Nothing you enter leaves your browser.

For reference only. This tool assumes a static liquid column of constant density, with no correction for temperature or compressibility. A pressure difference from it is not sufficient evidence of well control safety. Check every result by hand and against your own procedure before relying on it.

Hydrostatic pressure: calculation record

Inputs

bar abs
m/s²

Use true vertical depth, not measured depth. On a deviated well the two differ, and using measured depth overstates the pressure.

Results —

Hydrostatic head—
Pressure at depth—
Fluid gradient—

Hydrostatic head is a pressure difference, so it is the same in absolute and gauge terms. Pressure at depth is the surface pressure plus the head.

Calculated with the WellVigil hydrostatic pressure and fluid replacement calculator, wellvigil.co.uk, on . For reference only.

Engineering reviewer: ______________________   Date: ____________

How it is calculated

hydrostatic head (bar) = density (kg/m³) × true vertical depth (m) × gravity (m/s²) / 100,000
pressure at depth      = surface pressure + hydrostatic head
fluid gradient (bar/m) = density × gravity / 100,000
change in head         = (replacement density − original density) × vertical interval × gravity / 100,000

A gauge surface pressure is converted to absolute by adding the atmospheric pressure entered. Density given as specific gravity is multiplied by 1,000 kg/m³.

What it does not do