Leak rate calculator for pressure tests

Work out the apparent loss rate from a gas or liquid pressure test, from the start and end readings. Type your figures into the blue boxes; the results update as you type. Nothing you enter leaves your browser.

All free tools  ·  Tubing and annulus volume  ·  Hydrostatic pressure and fluid replacement  ·  Gas pressure and volume

For reference only. This tool reports an apparent rate from two readings. It is not proof of a leak, it applies no acceptance limit of its own, and it does not approve a barrier. Check every result by hand and against your own procedure before relying on it.

Gas leak rate: calculation record

Test inputs

bar abs
bar abs
°C
°C
m³
m³
min
bar abs
°C
std L/min

Pressures must be absolute, not gauge. Use Z factors for your gas at each condition, and temperatures that represent the gas, not the air around it.

Results —

Average equivalent rate—standard L/min
Average equivalent rate—standard m³/day
Standard-volume equivalent of the loss—standard m³
Initial gas inventory—mol
Final gas inventory—mol
Apparent inventory loss—mol (signed)
Final pressure if nothing were lost—bar abs, Z = 1
Against your limitNot assessednot approval

The rate is the apparent change in the amount of gas in a closed volume, expressed at standard conditions. A negative rate means the readings show more gas at the end than at the start.

Calculated with the WellVigil leak rate calculator, wellvigil.co.uk, on . For reference only: comparisons relate only to the limit entered by the user, and no barrier status is approved.

Engineering reviewer: ______________________   Date: ____________

Test procedure and source of the limit: ______________________________________

How it is calculated

Both methods use two readings, at the start and end of the test, and give an average rate over the elapsed time.

Gas

The amount of gas in the test volume is worked out at the start and at the end from the real gas law. The difference is converted to a volume at standard conditions and divided by the test time.

n = P V / (Z R T)                  amount of gas, mol (P in Pa, V in m³, T in K, R = 8.314462618 J/mol K)
loss = n(start) - n(end)
standard volume = loss × Z(std) × R × T(std) / P(std)
rate = standard volume / elapsed time

Liquid

The volume lost is the pressure drop multiplied by the compliance of the test boundary, with a first-order correction for any change in temperature.

loss (cc) = compliance × (P start - P end)
          + liquid volume (cc) × (liquid expansion - boundary expansion) × (T end - T start)
rate = loss / elapsed time
collected rate = collected volume / collection duration

What it does not do