WellVigil home Request a demo
Free engineering tool

Gas pressure and volume calculator

Work out the volume a fixed amount of gas occupies after its pressure and temperature change, for example a gas cap in an annulus. Nothing you enter leaves your browser.

For reference only. This tool treats the gas as a fixed mass and uses the Z factors you enter; it does not calculate them. It is not a cavern, production or brine displacement model. Check every result by hand and against your own procedure before relying on it.

Gas pressure and volume: calculation record

Inputs

bar abs

With both Z factors at 1 the gas is treated as ideal. For a real gas, take Z at each condition from a validated equation of state or PVT model.

Results —

Final gas volume—
Change in volume—
Relative change in volume—%

A negative change means the gas has been compressed into a smaller volume.

Calculated with the WellVigil gas pressure and volume calculator, wellvigil.co.uk, on . For reference only.

Engineering reviewer: ______________________   Date: ____________

How it is calculated

P1 V1 / (Z1 T1) = P2 V2 / (Z2 T2)          fixed mass of gas, absolute pressure, temperature in kelvin
V2 = V1 × (P1 / P2) × (T2 / T1) × (Z2 / Z1)
change = V2 − V1

A gauge pressure is converted to absolute by adding the atmospheric pressure entered.

What it does not do

Keeping this for every well? WellVigil stores each well's barrier schematic, strings, fluids, wellhead tests and annulus pressures in one place, and shows which wells need attention and why. Request a demo.