Gas pressure and volume calculator
Work out the volume a fixed amount of gas occupies after its pressure and temperature change, for example a gas cap in an annulus. Nothing you enter leaves your browser.
Gas pressure and volume: calculation record
Inputs
With both Z factors at 1 the gas is treated as ideal. For a real gas, take Z at each condition from a validated equation of state or PVT model.
Results —
A negative change means the gas has been compressed into a smaller volume.
Calculated with the WellVigil gas pressure and volume calculator, wellvigil.co.uk, on . For reference only.
Engineering reviewer: ______________________ Date: ____________
How it is calculated
P1 V1 / (Z1 T1) = P2 V2 / (Z2 T2) fixed mass of gas, absolute pressure, temperature in kelvin V2 = V1 × (P1 / P2) × (T2 / T1) × (Z2 / Z1) change = V2 − V1
A gauge pressure is converted to absolute by adding the atmospheric pressure entered.
What it does not do
- It does not calculate Z, and it does not check that the Z factors you enter suit your gas.
- It does not allow for gas dissolving in or coming out of a liquid.
- It does not allow for gas entering or leaving the volume. For that, use the leak rate calculator.
Keeping this for every well? WellVigil stores each well's barrier schematic, strings, fluids, wellhead tests and annulus pressures in one place, and shows which wells need attention and why. Request a demo.